Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Mech Behav Biomed Mater ; 21: 195-201, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23566771

RESUMO

Science and design are two completely separated areas of expertise with their own specialists. Science analyses the existing world to create new knowledge, design uses existing knowledge to create a new world. This tunnel-vision mentality and narrow-minded approach is dangerous for problem solving, where a broad view on potential solutions is required to realise a high-quality answer on the defined problem. We state that design benefits from scientific methods, resulting in a more effective design process and in better products, while science benefits from a design approach, resulting in more efficient and effective results. Our philosophy is illustrated using examples from the field of biomedical engineering. Both methods can benefit tremendously from each other. By applying scientific methods, superior choices will be made in the design process. With design, more accurate, effective and efficient science will be performed.


Assuntos
Desenho de Equipamento/métodos , Pesquisa , Ciência/métodos
2.
Head Neck ; 33(8): 1184-90, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21448981

RESUMO

BACKGROUND: The purpose of this study was to improve attachment of automatic tracheostoma valves, the knowledge on tracheostoma geometry, and its clinical influences preferred. This article investigates whether the number of removed trachea rings, incision of the sternocleidomastoid muscles, neck dissection, reconstruction, time after operation, and age have any effect on the (peri)stomal geometry of the patient. METHODS: (Peri)stomas of 191 patients from 10 institutes worldwide were photographed, measured, and compared. RESULTS: Paired comparisons between the number of trachea rings removed showed significant differences in horizontal and vertical trachea-opening diameters, but failed to demonstrate an effect in the depth of the stoma. T tests did not demonstrate significant differences in peristomal geometry between the sternocleidomastoid-cleaved and non-cleaved group. CONCLUSION: The number of removed tracheal rings during laryngectomy does not seem to influence stoma depth. However, this study does not demonstrate that cleaving the sternocleidomastoid muscle (SCM) at the time of a laryngectomy will result in a geometrically flatter stoma.


Assuntos
Neoplasias Laríngeas/reabilitação , Neoplasias Laríngeas/cirurgia , Laringectomia/métodos , Músculos do Pescoço/cirurgia , Traqueostomia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Cooperação Internacional , Neoplasias Laríngeas/patologia , Laringectomia/reabilitação , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Países Baixos , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/terapia , Prognóstico , Qualidade de Vida , Medição de Risco , Perfil de Impacto da Doença , Medida da Produção da Fala , Estomas Cirúrgicos , Traqueostomia/reabilitação , Resultado do Tratamento , Qualidade da Voz
3.
Ann Otol Rhinol Laryngol ; 120(12): 814-9, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22279953

RESUMO

OBJECTIVES: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops. This method makes long sentences or pauses difficult. The novel iValve is designed to allow almost natural speech, with mid-sentence pausing and whispering. METHODS: The inhalation closing flows and exhalation opening pressures of 6 iValve prototype versions at different settings were compared with physiological values. The airflow resistance at inhalation was compared to physiological values and to commercial valve values. RESULTS: The iValve prototypes showed flow and pressure ranges in concordance with the physiological values in the literature. The airflow resistance in the breathing mode was within the physiological airflow resistance range, yet above the values from the two commercial valves. The resistance in the speaking mode was above the physiological airflow resistance range. CONCLUSIONS: In vitro tests show that the iValve versions can be selected and adjusted to operate within the physiological range. The airflow resistance in the breathing mode is good. In speaking mode, inhalation should, and can, be decreased. The iValve should offer the patient a more intuitively useable alternative with more dynamic speech. Its low cost allows disposability and wider use.


Assuntos
Laringectomia/reabilitação , Laringe Artificial , Desenho de Equipamento , Humanos , Teste de Materiais , Pressão , Voz Alaríngea/instrumentação , Traqueostomia/instrumentação
4.
J Oral Maxillofac Surg ; 67(4): 782-7, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19304035

RESUMO

PURPOSE: To determine the mechanical strength and stiffness of the new 2.1 mm biodegradable ultrasound-activated SonicWeld Rx (Gebrüder Martin GmbH & Co, Tuttlingen, Germany) osteofixation system in comparison with the conventional 2.1 mm biodegradable Resorb X (Gebrüder Martin GmbH & Co) osteofixation system. MATERIALS AND METHODS: Plates and screws were fixed to 2 polymethylmethacrylate blocks to simulate bone segments and were subjected to tensile, side bending, and torsion tests. During testing, force and displacement were recorded and graphically presented in force-displacement diagrams. For the tensile tests, the strength of the osteofixation system was measured. The stiffness was calculated for the tensile, side bending, and torsion tests. RESULTS: The tensile strength and stiffness as well as the side bending stiffness of the SonicWeld Rx system presented up to 11.5 times higher mean values than the conventional Resorb X system. The torsion stiffness of both systems presents similar mean values and standard deviations. CONCLUSIONS: The SonicWeld Rx system is an improvement in the search for a mechanically strong and stiff as well as a biodegradable osteofixation system. Future research should be done to find out whether the promising in vitro results can be transferred to the in situ clinical situation.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis/química , Dispositivos de Fixação Ortopédica , Poliésteres/química , Pinos Ortopédicos , Placas Ósseas , Parafusos Ósseos , Elasticidade , Falha de Equipamento , Humanos , Teste de Materiais , Maleabilidade , Polimetil Metacrilato/química , Estresse Mecânico , Temperatura , Resistência à Tração , Fatores de Tempo , Torção Mecânica , Ultrassom , Vibração , Água/química
5.
Head Neck ; 30(9): 1156-66, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18642281

RESUMO

BACKGROUND: A newly developed artificial voice source was clinically evaluated in laryngectomized women for voice quality improvements. The prosthesis was placed in a commercially available, tracheoesophageal shunt valve. METHODS: In 17 subjects, voice-producing element (VPE) prototypes were compared with the subject's regular tracheo-esophageal shunt voice in a randomized cross-over trial. The evaluation was based on aeroacoustic measurements and perceptual analysis. RESULTS: Considerably higher fundamental frequencies were attained with the use of the VPE. The sound pressure level also increased for most subjects. The required driving pressures of the lung and air flow rates were altered, allowing significantly longer phonation times in 1 breath. Accumulation of mucus did not interfere with the proper functioning of the device during these tests. CONCLUSION: A VPE with sound-generating membranes is suitable for providing a substitute voice source for laryngectomized patients, especially patients suggestive of a severely hypotonic or atonic pharyngoesophageal segment who can benefit from a more melodious and louder voice.


Assuntos
Neoplasias Laríngeas/reabilitação , Laringectomia/métodos , Laringe Artificial , Voz Alaríngea/instrumentação , Idoso , Estudos de Coortes , Feminino , Humanos , Neoplasias Laríngeas/patologia , Neoplasias Laríngeas/cirurgia , Laringectomia/efeitos adversos , Pessoa de Meia-Idade , Desenho de Prótese , Implantação de Prótese , Qualidade de Vida , Sensibilidade e Especificidade , Inteligibilidade da Fala , Medida da Produção da Fala , Voz Alaríngea/métodos , Resultado do Tratamento
6.
J Oral Maxillofac Surg ; 65(11): 2148-58, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17954307

RESUMO

PURPOSE: To present relevant mechanical data to simplify the selection of an osteofixation system for situations requiring immobilization in oral and maxillofacial surgery. MATERIALS AND METHODS: Seven biodegradable and 2 titanium osteofixation systems were investigated. The plates and screws were fixed to 2 polymethylmethacrylate (PMMA) blocks to simulate bone segments. The plates and screws were subjected to tensile, side bending, and torsion tests. During tensile tests, the strength of the osteofixation system was monitored. The stiffness was calculated for the tensile, side bending, and torsion tests. RESULTS: The 2 titanium systems (1.5 mm and 2.0 mm) presented significantly higher tensile strength and stiffness compared with the 7 biodegradable systems (2.0 mm, 2.1 mm, and 2.5 mm). The 2.0 mm titanium system showed significantly higher side bending and torsion stiffness than the other 8 systems. CONCLUSION: Based on the results of the current study, it can be concluded that the titanium osteofixation systems were (significantly) stronger and stiffer than the biodegradable systems. The BioSorb FX (Linvatec Biomaterials Ltd, Tampere, Finland), LactoSorb (Walter Lorenz Surgical Inc, Jacksonville, FL), and Inion (Inion Ltd, Tampere, Finland) 2.5 mm systems have high mechanical device strength and stiffness compared with the investigated biodegradable osteofixation systems. With the cross-sectional surface taken into account, the Biosorb FX system (with its subtle design) proves to be the far more superior system. The Resorb X (Gebrüder Martin GmbH & Co, Tuttlingen, Germany) and MacroPore (MacroPore Biosurgery Inc, Memphis, TN) systems present to be, at least from a mechanical point of view, the least strong and stiff systems in the test.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis , Placas Ósseas , Parafusos Ósseos , Titânio , Materiais Biocompatíveis/química , Dioxanos/química , Elasticidade , Humanos , Ácido Láctico/química , Teste de Materiais , Poliésteres , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Polímeros/química , Polimetil Metacrilato/química , Rotação , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Titânio/química , Torque
7.
J Oral Maxillofac Surg ; 65(11): 2142-7, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17954306

RESUMO

PURPOSE: To determine 1) the differences in maximum torque between 7 biodegradable and 2 titanium screw systems, and 2) the differences of maximum torque between "hand tight" and break of the biodegradable and the titanium osteofixation screw systems. MATERIALS AND METHODS: Four oral and maxillofacial surgeons inserted 8 specimens of all 9 screw systems in polymethylmethacrylate plates. The surgeons were instructed to insert the screws as they would do in the clinic (hand tight). The data were recorded by a torque measurement meter. A PhD resident inserted 8 specimens of the same set of 9 screw systems until fracture occurred. Likewise, the maximum applied torque was recorded. RESULTS: 1) The mean maximum torque of the 2 titanium screw systems was significantly higher than that of the 7 biodegradable screw systems, and 2) the mean maximum torque for hand tight was significantly lower than for break in 2 biodegradable, and both titanium screw systems. CONCLUSIONS: Based on the results, we conclude that the 1.5 mm and 2.0 mm titanium screw systems still present the highest torque strength compared with the biodegradable screw systems. When there is an intention to use biodegradable screws, we recommend the use of 2.0 mm BioSorb FX (Linvatec Biomaterials Ltd, Tampere, Finland), 2.0 mm LactoSorb (Walter Lorenz Surgical Inc, Jacksonville, FL), or the larger 2.5 mm Inion (Inion Ltd, Tampere, Finland) screws.


Assuntos
Implantes Absorvíveis , Materiais Biocompatíveis , Parafusos Ósseos , Titânio , Materiais Biocompatíveis/química , Dioxanos/química , Desenho de Equipamento , Falha de Equipamento , Humanos , Ácido Láctico/química , Teste de Materiais , Poliésteres , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Polímeros/química , Polimetil Metacrilato/química , Rotação , Estresse Mecânico , Propriedades de Superfície , Titânio/química , Torque
8.
Lab Anim ; 41(2): 270-84, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17430627

RESUMO

A modern way of voice rehabilitation after total laryngectomy includes the use of shunt valves and tracheostoma valves. Problems of fixation to the surrounding tissue are a major drawback in the use of the shunt valve, heat and moisture exchange (HME) filters and, especially, the tracheostoma valve. To solve these problems different tissue connectors were developed. The main objective was to test the feasibility of these prototypes in a new animal model. Here we discuss the results, problems and complications of the selected Saanen goat model. In this prospective laboratory study, 19 healthy adult female Saanen goats (Capra hircus) were used and observed post-surgically for 12 weeks. Selection criteria such as comparable anatomy to humans and easy handling were used for animal model development. Also a literature search using the Medline and the ISI Web of Science databases was performed. The anatomy of the Saanen goat was investigated in a separate postmortem study. Surgery consisted of a laryngotracheal separation and implantation of a tracheo-oesophageal and tracheostoma tissue connector with fibrin tissue glue. Postoperative care consisted of frequent stoma care, monitoring appetite, weight, vital signs and administration of antibiotics, analgesics and mucolytic agents. All animals survived the surgical procedure. However, postoperative care was extensive, labour intensive and was accompanied by several complications. Eleven animals died spontaneously before the end of the experiment. The tracheostoma tissue connector caused signs of local infection in all cases. There was no evidence of infection around the tracheo-oesophageal tissue connector in 18 cases. It was concluded that the use of goats in this tracheostoma model was associated with major complications and should, therefore, only be used for short-term experiments with intensive care. Additional research is needed to see if clinical application of the tissue connectors is possible in the future.


Assuntos
Cabras/anatomia & histologia , Laringectomia/veterinária , Modelos Animais , Animais , Feminino , Implantes Experimentais , Laringectomia/instrumentação , Laringectomia/métodos , Período Pós-Operatório , Traqueostomia
9.
J Biomed Mater Res A ; 82(1): 62-72, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17269137

RESUMO

In cancer patients who have undergone total surgical removal of the larynx, ideally voice rehabilitation should be performed using a shunt valve (placed in a fistula of the tracheo-esophageal wall) and a tracheostoma valve (TSV) to enable hands-free tracheo-esophageal speech. A tracheostoma is created by suturing the trachea into the lower anterior part of the neck, and a TSV is a device that can be placed at the stoma. Unfortunately, many patients are unable to use a TSV, mainly due to fixation difficulties. To improve the fixation of the TSV, tracheostoma tissue connector (TS-TC) prototypes have been designed. Prototype 1 consisted of a titanium ring, inner diameter 30 mm, with a circular polypropylene mesh glued to it with silicone adhesive. Four holes had been drilled into the ring for the insertion of sub- and percutaneous screws. Prototype 2 consisted of a silicone rubber ring, inner diameter 30 mm, combined with polypropylene mesh and four titanium inserts that functioned as a base plate for the insertion of sub- and percutaneous screws. In adult female goats a tracheostoma was created and the prototypes were implanted. After 6 weeks of subcutaneous implantation, percutaneous screws were inserted. After twelve weeks, the experiment was terminated and the implants with the surrounding tissues were processed and examined histologically. The clinical appearance during weeks 7-12 varied from very poor to relatively good. Histologically, the implants showed a uniform inflammatory response. We found that all the tissue surrounding the screws showed signs of epithelial down growth. It was concluded that the two-stage implantation procedure of our prototype TS-TCs in this animal model was unsuccessful. Additional research efforts are necessary to improve tissue immobilization and to devise reliable fixation systems for TSVs.


Assuntos
Materiais Biocompatíveis , Laringe Artificial , Traqueostomia , Animais , Materiais Biocompatíveis/efeitos adversos , Feminino , Cabras , Humanos , Laringe Artificial/efeitos adversos , Teste de Materiais , Microscopia Eletrônica de Varredura , Polipropilenos , Desenho de Prótese , Elastômeros de Silicone , Voz Esofágica , Titânio
10.
Head Neck ; 29(7): 665-74, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17252591

RESUMO

BACKGROUND: A sound generator based on a double-membrane design that fits into a regular tracheoesophageal shunt valve may improve voice quality after total laryngectomy in patients rehabilitated with surgical voice prostheses. METHODS: Voice-producing element (VPE) prototypes were manufactured using medical grade biocompatible materials and tested in vitro under physiological conditions. RESULTS: Basic sound, containing multiple harmonics, was successfully produced under physiologic air pressure and airflow conditions. The fundamental frequency and sound pressure level (SPL) is controlled by changing the driving pressure, thus enabling sufficient intonation for day-to-day speech. The obtained frequency range (190-350 Hz) is appropriate for producing a female voice. The low noise-to-harmonics ratio (mean 0.15) and also the efficiency of sound production (5.5 x 10(-5) at 80 dB(A) and 0.15 m microphone distance) is comparable to that of normal vocal folds. CONCLUSIONS: Functional restoration of the voice after laryngectomy with a double-membrane VPE appears to be a feasible concept for female laryngectomized patients with a hypotonic, or atonic pharyngoesophageal segment.


Assuntos
Laringe Artificial , Modelos Biológicos , Acústica da Fala , Voz Alaríngea/instrumentação , Pressão do Ar , Humanos , Técnicas In Vitro , Laringectomia , Teste de Materiais , Desenho de Prótese , Medida da Produção da Fala/instrumentação , Qualidade da Voz
11.
Head Neck ; 28(11): 982-9, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16906515

RESUMO

BACKGROUND: After total laryngectomy and voice rehabilitation using a tracheoesophageal shunt valve, patients often have valve-related complications such as leakage. To solve these problems, a tracheoesophageal tissue connector (TE-TC) was devised to serve as an interface between the patient's tissue (trachea and esophagus) and the shunt valve. METHODS: The TE-TC is a permucosal connection constructed from a titanium ring (filled with a silicon rubber plug) combined with polypropylene or titanium mesh. After implantation in adult goats for 12 weeks the implants were submitted to histologic investigation. RESULTS: Firm implant fixation was achieved. In nearly all (18/19), no signs of infection of the implant were seen; 11 of 19 animals died before the end of the experiment owing to complications not related to the implant. CONCLUSIONS: The TE-TC is a new device with potential in the solution for fixation-related problems in tracheoesophageal voice rehabilitation.


Assuntos
Implantes Experimentais , Voz Alaríngea/instrumentação , Animais , Feminino , Cabras , Laringectomia , Modelos Animais , Polipropilenos , Telas Cirúrgicas , Titânio , Fístula Traqueoesofágica/patologia , Fístula Traqueoesofágica/cirurgia , Traqueostomia
12.
J Biomed Mater Res B Appl Biomater ; 79(2): 236-44, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16680715

RESUMO

Reprocessing of single-use devices is an upcoming issue in the Western world, but has been for many years in developing countries. In developing countries, the number of bone fractures due to traffic or industrial accidents is high. Patients often need an osteosynthesis with plates and screws, but most patients, however, cannot afford this because of the costs involved and have to rely on the application of used plates and screws. This study aims to determine whether used plates can be safely reused in another patient from a biomechanical, surface physico-chemical, and biological point-of-view. Osteosynthesis plates weakened in a predictable way during use, regardless of the history, presumably because tests were conducted under extreme conditions in the absence of clinically applied load-sharing between bone and plate. Surface physico-chemical analyses indicated that used plates and screws were more hydrophilic than new ones; had increased amounts of calcium-phosphates at their surfaces; and possessed higher number of scratches. Pitting corrosion could be seen on SEM micrographs. Simple cleaning methods, as available in developing countries, including toothbrush, water, detergent and bleach yielded elemental surface compositions, and hydrophobicities similar to those of new ones, while biologically thus cleaned screws were not cytotoxic according to ISO-10993-5 and endotoxin release according to USP-27-NF-22 was within the requirements of the FDA. It is concluded that the reuse of osteosynthesis plates and screws is not necessarily unsafe, although preferably a register should be kept of all previous users to limit the number of reuses as mechanical weakening does occur.


Assuntos
Materiais Biocompatíveis , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Adolescente , Adulto , Materiais Biocompatíveis/química , Criança , Países em Desenvolvimento , Reutilização de Equipamento , Humanos , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...